Inactivation of adenovirus using low-dose UV/H2O2 advanced oxidation

Imagen de Roberto A Rodriguez
PDF versionPDF version
TítuloInactivation of adenovirus using low-dose UV/H2O2 advanced oxidation
Publication TypeJournal Article
Year of Publication2012
AutoresBounty, S, Rodriguez, RA, Linden, KG
JournalWater ResWater Res
Volume46
Pagination6273-8
Date PublishedDec 1
ISBN Number1879-2448 (Electronic)0043-1354 (Linking)
Accession Number23040991
AbstractAdenovirus has consistently been observed to be the most resistant known pathogen to disinfection by ultraviolet light. This has had an impact on regulations set by the United States Environmental Protection Agency regarding the use of UV disinfection for virus inactivation in groundwater and surface water. In this study, enhancement of UV inactivation of adenovirus was evaluated when hydrogen peroxide was added to create an advanced oxidation process (AOP). While 4 log reduction of adenovirus was determined to require a UV dose (UV fluence) of about 200 mJ/cm(2) from a low pressure (LP) UV source (emitting at 253.7 nm), addition of 10 mg/L H(2)O(2) achieved 4 log inactivation at a dose of 120 mJ/cm(2). DNA damage was assessed using a novel nested PCR approach, and similar levels of DNA damage between the two different treatments were noted, suggesting the AOP enhancement in inactivation was not due to additional DNA damage. Hydroxyl radicals produced in the advanced oxidation process are likely able to damage parts of the virus not targeted by LPUV, such as attachment proteins, enhancing the UV-induced inactivation. The AOP-enhanced inactivation potential was modeled in three natural waters. This research sheds light on the inactivation mechanisms of viruses with ultraviolet light and in the presence of hydroxyl radicals and provides a practical means to enhance inactivation of this UV-resistant virus.